Glycol degradation
Hampton Research measured pH and conductivity of 8 different polyethylene glycols stored in a variety of typical laboratory storage settings over a period of 18 months.
Aqueous solutions of ethylene glyco land propylene glycol produce acidic degradation products upon thermal oxidation. This results in a decrease in pH of the aqueous solutions which could accelerate the corrosion of metallic components of solar collectors. The increase in the concentrations of degradation products in solution was measured over time using the Ion Chromatography Exclusion(ICE) method of analysis
- http://fire.nist.gov/bfrlpubs/build85/PDF/b85009.pdf Solar DEGRADED AQUEOUS GLYCOL SOLUTIONS...]
Analyzers
The Fluid Property Analyzer utilizes a tuning fork mechanical resonator whose method of simultaneously and directly measuring viscosity, density and dielectric constant is patented.
The sensor is resistant to contamination and corrosive degradation from materials such as particles, fuel, ethylene glycol, wear metals, acids and bases.
MEAS Sensors
The FPS2820B12C4 is a novel fluid property sensor that will directly and simultaneously measure the viscosity, density, dielectric constant and temperature of fluids. Relying on patented tuning fork technology, the sensor monitors the direct and dynamic relationship between multiple physical properties to identify a wide variety of fuels like marine heavy fuel oil, light fuel oil or kerosene.
The FPS2810B12C4 is a novel Oil Quality sensor that directly and simultaneously monitors the quality of fluids such as engine oil, transmission and brake fluid, hydraulic and gear oils